cisco me 3400e specs. 2(55)SE September 2010 Text Part Number: OL-9641-06. cisco me 3400e specs

 
2(55)SE September 2010 Text Part Number: OL-9641-06cisco me 3400e specs com search results

The documentation set for this product strives to use bias-free language. Bias-Free Language. - Cisco ME 3400EG-2CS-A Switch. Cisco ME 3400-24TS-A Switch - Retirement Notification. Cisco ME. Connector and Cable Specifications • Connector Specifications • Cables and Adapters. For a complete description command descriptions, see. Cisco announces the end-of-sale and end-of-life dates for the Cisco ME 3800X Series Carrier Ethernet Switch Routers. Book Title. Cisco ME 3400E Series Ethernet Access Switches. The Cisco ME 3400E Series offers two different Cisco IOS® Software feature images. THE SPECIFICATIONS AND INFORMATION REGARDING THE. End-of-Sale Date: 2014-01-09. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Rel. The Cisco ME 3400E switch supports these features: a switchport-based model; all-to-one bundling; service multiplexing (complex UNI) split horizon (Cisco IOS Release 12. Processor board ID FOC1225U08D Last reset from power-on 5 Virtual Ethernet interfaces 24 FastEthernet interfaces 2 Gigabit Ethernet interfaces The password-recovery mechanism is enabled. Bias-Free Language. " For information on configuring IPv6 access control lists (ACLs) see Chapter 38, "Configuring IPv6 ACLs. Note Only UNIs or ENIs can be dynamic-access ports. Archiving Software Images Before upgrading your switch software, make sure that you have archived copies of the current Cisco IOS release and the Cisco IOS release to which you are upgrading. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Cisco IOS Release 12. - Cisco ME 3400EG-2CS-A Switch. Telstra have told us that we can connect the V7610 to a. Connector and Cable Specifications. 2(58)SE January 2012 Text Part Number: OL-9641-07. 20. The documentation set for this product strives to use bias-free language. 9 x 44. For the purposes of this documentation set,. You can view a listing of available Switches offerings that best meet your specific needs. com search results. 0 KB) View with Adobe Reader on a variety of devicesCisco ME 3400E Series Ethernet Access Switches. Register now . Configuration Guides. If the switch is running the metro IP access image, there is no limit to the number of NNIs that can be. Step 1. 対象読者. It provides both high. 2(58)SE. 170 West Tasman Drive San Jose, CA 95134-1706 USA Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527. accessing through console port C-1. This guide is for the networking professional using the Cisco IOS command-line interface (CLI) to manage the Cisco Metro Ethernet (ME) 3400E Series Ethernet Access switch, hereafter referred to as the switch. Connect the adapter cable to the console connector on the switch front panel. 2(55)SE. Cisco ME 3400E Series Ethernet Access Switches. 01-07-2016 09:43 AM. We assume that you are familiar Table A-5 Technical Specifications for the Cisco ME 3400E-24TS-M . Cisco ME 3400E Switch Software Configuration Guide, Release 12. The last day to order the affected product(s) is January 4, 2019. ● IEEE 802. 45 x 24. Cisco ME 3400E イーサネット アクセス スイッチ ハードウェア インストレーション ガイド. Home; Cisco ME 3400E Series Ethernet Access Switches; Install and Upgrade  < Return to Cisco. Cisco ME. This guide describes the Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access switches system messages. Cisco IP SLAs is a part of Cisco IOS software that allows Cisco customers to analyze IP service levels for IP applications and services by using active traffic. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Cisco IOS Release 12. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial. In using our site, you consent to the use of these cookies and other technologies. Packets that fail to meet any of the matching. • Four leads of 16-gauge copper wire. Product ID: WS-C2950G-48-EI. The documentation set for this product strives to use bias-free language. Bias-Free Language. The documentation set for this product strives to use bias-free language. Configuration Guides. Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide. You can configure all of these features when your switch is running per-VLAN spanning-tree plus (PVST+). 12. 75 x 9. Statement 1003 1 Cisco ME 3400E switch 6 Cable guide 2 Documentation 7 Four number-10 Phillips truss-head screwsEnd-of-Sale and End-of-Life Announcement for the Cisco ME 3400E Series Ethernet Access Switches. Operating Temperatures for the Cisco ME 3400E-24TS-M. † Look for loose connections. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability,. Cisco ME 3400EG-2CS-A Switch - Cisco ME 3400E Series Ethernet Access Switches - Service Provider Switches - Ethernet Access - Switches - Cisco Products. This chapter consists of these sections: • Managing the System Time and Date • Configuring a System Name and Prompt • Creating a Banner • Managing the MAC Address Table • Managing the ARP Table. The switch can use the per-VLAN spanning-tree plus (PVST+) protocol based on the IEEE 802. 35 lb (2. 2(58)EX; Index; Command Reference. 1Q VLAN ● IEEE 802. Connector and Cable Specifications • Connector Specifications • Cables and Adapters. 12. Cisco Systems ME-3400E-24TS-M Specifications: ME3400E Ethernet Access-Switch 24 10/100 + 2 Combo. that packet is considered a member of the class and is forwarded according to the QoS specifications set in the traffic policy. Bias-Free Language. 2(60) for Cisco ME 3400E Series Ethernet Access Switches ; End-of-Sale and End-of-Life Announcement for the Cisco ME 3400E Series Ethernet Access Switches ; End-of-Sale and End-of-Life Announcement. Figure 1-1 Cisco ME 3400E-24TS-M Front Panel Table 1-1 Cisco ME 3400E Models and Descriptions Switch Model Description Cisco ME 3400E-24TS-M 24 10/100 FastEthernet downlink ports and 2 dual-purpose ports (2 10/100/1000BASE-T copper ports and 2 SFP1 module slots); supports removable AC- and DC-power supplies. Products. End-of-Sale Date: 2014-01-09. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability,. The Cisco ME. Table A-5 Technical Specifications for the Cisco ME 3400E-24TS-M . 2(60) for Cisco ME 3400E Series Ethernet Access Switches. Bias-Free Language. Product Information. Like many companies, Cisco uses cookies and other technologies, some of which are essential to make our website work. Data link. The Cisco ME 3400E switch is a VMPS client. The Cisco ME 3400E series provides carrier-grade features such as redundant, integrated, field-replaceable power and fan modules that increase the uptime of business-critical services. 8 x 17. Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide OL-16447-01. Cisco ME 3400E イーサネット アクセス スイッチ ハードウェア インストレーション ガイド. 10/100 . This guide is. Cisco Small Business 110 Series Unmanaged Switches Data Sheet - Affordable 10/100/1000-Mbps speeds for even the most bandwidth-hungry applications; 5- to 24-port models that are desktop or rack mountable; Power over Ethernet models to provide power to IP phones, access points, and other devices; Works right out of the box: plug. Connector and Cable Specifications • Connector Specifications • Cables and Adapters. Environmental Ranges and Technical Specifications for the Switch . 100 to 240 VAC ±. Bias-Free Language. • Four-position DC-terminal-block connector from the accessory kit. Cisco ME3400E Ethernet Access Switch Software Configuration Guide, Rel 12. When the message "Send break character to prevent autobooting. xlvii Cisco ME 3400E Ethernet Access Switch Software Configuration Guide OL-16485-05 Preface † Cisco ME 3400E Switch Getting Started Guide † Regulatory Compliance and Safety Information for the Cisco ME 3400E Ethernet Access Switch † Cisco Small Form-Factor Pluggable Modules Installation Notes † Cisco CWDM GBIC and CWDM SFP. - Cisco ME 3400EG-12CS-M Switch. Administered: yes. Exchange the suspect module with known good. 1Q tag. Cisco's End-of-Life Policy. 2(58)SE January 2012 Text Part Number: OL-9641-07. Cisco ME 3400E Series Ethernet Access Switches. 10/100 . Table A-1 Environmental Ranges for the Switch . 512K bytes of flash-simulated non-volatile configuration memory. PDF - Complete Book (4. 45 x 24. 170 West Tasman Drive San Jose, CA 95134-1706. Cisco ME 3400E Ethernet Access Switch Command. com search results. 170 West Tasman Drive San Jose, CA 95134-1706. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial. This warning applies to only the Cisco ME 3400E-24TS-M and the Cisco ME 3400EG-12CS-M switches: Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. Technical Specifications† To power on the Cisco ME 3400E-24TS-M and Cisco ME 3400EG-12CS-M, see Chapter 3, “Installing and Removing AC- and DC-Power-Supply Modules. If you want support information for the Cisco ME 3400-24TS-D Switch documentation, it may be available through Cisco. Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switches System Message Guide Cisco IOS Release 12. Beginning with Cisco IOS Release 12. 2(50)SE. 800 553-NETS (6387) Fax: 408 527-0883 Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switches System Message Guide Cisco IOS Release 12. Dimensions (H x W x D) 1. See Table A-2, Table A-3, and Table A-4. Bias-Free Language. 2(52)SE OL-19711-01 Hardware Supported † New Features, page 6 † Minimum Cisco IOS Release for Major Features, page 7 † Limitations and Restrictions, page 10 † Open Caveats, page 16 † Resolved Caveats, page 16 † Documentation. Step 3. Starting with Cisco IOS Release 12. The Cisco ME 3400E switch is a VMPS client. With carrier-grade features such as modular Field-Replaceable Units (FRUs), dying gasp for loss of power, and alarm contacts to detect changes in environmental conditions, the Cisco ME 3400EG-12CS is ideally positioned as an in-building aggregator for high-density buildings where multiple access devices are needed. このマニュアルは、Cisco IOS コマンドライン インターフェイス(CLI)を使用して Cisco Metro Ethernet(ME)3400E シリーズ イーサネット アクセススイッチ(以降、 スイッチ )を管理するネットワーキング専門家を対象としています。 このマニュアルは、すでに Cisco IOS コマンドおよび. Cisco ME 3400E and ME 3400 metro IP access cryptographic image with Kerberos, SSH, Layer 2+, and full Layer 3 routing Metro Ethernet features. For information about configuring IPv4 unicast routing, see Chapter 36, "Configuring IP Unicast Routing. The documentation set for this product strives to use bias-free language. 1w ● IEEE 802. 2 (44) - 12. In access-map. 2(58)EZ. Cisco ME 3400E Series Ethernet Access Switches. Bias-Free Language. View online or download Cisco ME 3400 Series Software Configuration Manual, Command Reference Manual, System Message Manual, Hardware Installation Manual. 2(60)EZ and Later OL-29325-07 Hardware Support SFP modules ME 3400 1000BASE-T, -BX, -SX, -LX/LH, -ZX 100BASE-BX, FX, -LX Coarse wavelength-division multiplexing (CWDM)The Cisco ME 3400E Series comes by default with advanced Layer 2 VPN service features and the option to upgrade to Layer 3 VPN services, giving service providers an out-of-the-box business VPN solution that can be scaled to meet future needs. Beginning in privileged EXEC mode, follow these steps to enable and configure RIP:. The Cisco ME 3400 series will continue to be the standard access product for business. com Cisco ME 3400E Series Ethernet Access Switches Data Sheet ; End-of-Life and End-of-Sale Notices; English. 2 Release Notes for the Cisco ME 3400E and ME 3400 Ethernet Access Switches, Cisco IOS Release 12. 2(44)EY. Secure with the retainer clip and the bushing. Bias-Free Language. com. You can configure only the noted features when your switch is running the Multiple Spanning Tree Protocol (MSTP) or the. 2(58)SE. A long time since this question has been posted but I just finished testing the ME3400E. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Cisco IOS Release 12. The documentation set for this product strives to use bias-free language. 2(60)EZ. 1D standard and Cisco proprietary extensions, or the rapid per-VLAN spanning-tree plus (rapid-PVST+). Bias-Free Language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability,. 2(58)EZ and any limitations, restrictions, and caveats that apply to the release. 1ad, a switchport is configured as either a customer user-network interface (C-UNI), a service-provider UNI (S-UNI), or a network-to-network interface. CISCO > SWITCHES Cisco ME 3400E Series Ethernet Access Switches UNI/ENI/NNI Default Behaviors Default Behaviors Benefits UNI/ENI default: Down Ports must be activated by the service provider before customers can receive service. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Rel. Beginning with Cisco IOS Release 12. SFP = small form. 72 MB) PDF - This Chapter (269. Physical Dimensions . The documentation set for this product strives to use bias-free language. Secure with the retainer clip and the bushing. Connector Specifications • 10/100 • SFP Module Connectors • Dual-Purpose Ports • 10/100 Ethernet Management Port • Alarm Input Port. Input voltage. 1. 52 x 17. Preface. 0 °F: Min operating temperature: 32. My next Guide will be about MPLS TE. Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide. Bias-Free Language. users must take full responsibility for their application of any products. This chapter describes how to create the initial switch configuration (for example, assigning the switch IP address and default gateway information) for the Cisco Metro Ethernet (ME) 3400E Ethernet Access switch by using a variety of automatic and manual methods. End-of-Sale Date: 2014-01-09. Modelli supportati: - Cisco ME 3400E-24TS-M Switch. Cisco ME 3400E Switch Software Configuration Guide, Release 12. Table A-1 lists the operational limits of the Cisco 812 ISR. For a complete description command descriptions, see. これらの製品は、広く導入されている Cisco ME 3400E シリーズ イーサネット アクセス スイッチに. 2(60)EZ and later, and any limitations, restrictions, and caveats that apply to the release. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Bias-Free Language. インストールとアップグレード ガイド. Configuration Guides. Bias-Free Language. A dynamic-access port can belong to one VLAN (VLAN ID 1 to 4094) and is dynamically assigned by a VMPS. This warning applies to only the Cisco ME 3400E-24TS-M and the Cisco ME 3400EG-12CS-M switches: Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. Connector Specifications • 10/100 • SFP Module Connectors • Dual-Purpose Ports • 10/100 Ethernet Management Port • Alarm Input Port. Chapter Title. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Rel. This guide describes the hardware features of the switch. Chassis configuration guide (63 pages). that packet is considered a member of the class and is forwarded according to the QoS specifications set in the traffic policy. New Original Cisco ME 3400 Switch - 24 10/100 + 2 SFP, DC PS. It provides both high availability and service flexibility. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability,. command-line interface . The last day to order the affected product(s) is May 31, 2019. Statement 1003 1 Cisco ME 3400E switch 6 Cable guide 2 Documentation 7 Four number-10 Phillips truss-head screwsFG-2600F FG-3000F FG-3200F FG-3300E FG-3400E Firewall Throughput (1518/512/64 byte UDP) 198 / 196 / 140 Gbps 397 / 389 / 221 Gbps 387 / 385 / 178. • ME 3400 and ME 3400E 24TS, 2CS, and 12 CS models supported ingress QoS classification for 254 unique VLAN IDs on the switch. The documentation set for this product strives to use bias-free language. Turn on power, and verify that the AC power-supply LED on the switch. The documentation set for this product strives to use bias-free language. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Cisco IOS Release 12. For the purposes of this documentation set,. If the switch is running the metro access image, only four ports on the switch can be configured as NNIs at one time. Connector and Cable Specifications • Connector Specifications • Cables and Adapters. Contents viii Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide OL-26665-01 HLFM Messages 2-31 IDBMAN Messages 2-32 IFMGR Messages 2-34 IGMP_QUERIER Messages 2-35 Cisco ME 3400E Series Ethernet Access Switches. Purpose . 4. 1. The documentation set for this product strives to use bias-free language. 12. Bias-Free Language. Cisco ME 3400E Series Ethernet Access Switches. Cisco ME-3400E-24TS-M Ethernet Access Switch with Layer 2 VPN Tested Working. WS-C2960G-24TC-L. The documentation set for this product strives to use bias-free language. Bias-Free Language. Cisco ME 3400E Series Ethernet Access Switches. Cisco's End-of-Life Policy. Chapter Title. Configuration Guides. Bias-Free Language. 12. Environmental Ranges and Technical Specifications for the Switch . 12. 12. Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide OL-26665-01 Preface Audience This guide is for the networking professional managing the Cisco Metro Ethernet (ME) 3400E, ME 3400, and ME 2400 Ethernet Access switches, hereafter referred to as the switch. CLI . cisco ME-3400-24FS-A (PowerPC405) processor (revision G0) with 131072K bytes of memory. The privileged command set. See CLI. 800 553-NETS (6387) Fax: 408 527-0883 Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switches System Message Guide Cisco IOS Release 12. If you want. Unterstützte Modelle: - Cisco ME 3400E-24TS-M-Switch. For information about configuring IPv4 unicast routing, see Chapter 36 "Configuring IP Unicast Routing. ME-3400-24TS-A. Bias-Free Language. Environmental Ranges . The Cisco ME 3400E series is an exciting addition to the Cisco ME 3400 series, one of the most successful Carrier Ethernet access switches in the world giving service providers greater availability, flexibility, manageability, and security. • Dual-hole ground lug from the switch accessory kit (for the Cisco ME 3400EG-2CS-A). In Figure 1-2, Cisco ME 3400E switches are used as UPEs in customer sites connected to customer-premises equipment (CPE). The Cisco ME 3400E series is an exciting addition to the Cisco ME 3400 series, one of the most successful Carrier Ethernet access switches in the world giving service providers greater availability, flexibility, manageability, and security. The documentation set for this product strives to use bias-free language. Bias-Free Language. This warning applies to only the Cisco ME 3400E-24TS-M and the Cisco ME 3400EG-12CS-M switches: Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. The. 12. During operation, the system software sends these messages to the console (and, optionally, to a logging server on another. You can view a listing of available Switches offerings that best meet your specific needs. The Cisco ME 3400E Series is the second-generation Cisco access switch optimised for Ethernet-to-the-Business (ETTB) VPN services. Bias-Free Language. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Release 12. Note For complete syntax and usage information for the commands used in this chapter, see the command reference for this release and the Cisco IOS Configuration Fundamentals. Cisco ME 3400E Series Ethernet Access Switches. View this content on Cisco. Bias-Free Language. The Cisco ME 3400E Series (Figure 1) includes the following configurations: Cisco ME 3400EG-12CS chassis (part number ME-3400EG-12CS-M) with 12 dual-purpose. The Cisco ME-3400-24TS-A is the Cisco ME 3400-24TS AC with 24 Ethernet 10/100 ports, two SFP uplinks, and an AC power supply. 16. Table A-1 Environmental Ranges for the Switch . It also describes how to modify the switch startup configuration. Bias-Free Language. 75 x 9. Show Platform CommandsYou can use Cisco ME 3400 switches to form Layer 2 VPNs so that customers at different locations can exchange information through a service-provider network without requiring dedicated connections. The Cisco ME 3400 Series Ethernet Access Switches has been retired and is no longer supported. 800 553-NETS (6387) Fax: 408 527-0883 Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switches System Message Guide Cisco IOS Release 12. ” † To power on the Cisco ME 3400EG-2CS-A, connect one end of the AC- power cord to the AC-power connector on the switch, and connect the other end of the power cord to an AC-power outlet. Table A-1 Environmental Ranges for the Switch . 2 (44) - 12. This guide is for the networking or computer technician installing the Cisco Metro Ethernet (ME) 3400E Series Ethernet Access switch, also known as the switch. The documentation set for this product strives to use bias-free language. End-of-Sale and End-of-Life Announcement for the Cisco IOS Release 12. Safety and Compliance. 3u 100BASE-T ●. In any network, Layer 2 and Layer 3 switches exchange control packets with other switches in the network. Home; Cisco ME 3400E Series Ethernet Access Switches; Configure  < Return to Cisco. † Cisco ME 3400E Ethernet Access Switch Power-Supply Module Quick Started Guide Describes the high-level steps for installing the AC- and DC-power modules for the Cisco ME 3400E-24TS-M and the Cisco ME 3400EG-12CS-M switches. The documentation set for this product strives to use bias-free language. 2(44)EY. These release notes include important information about Cisco IOS Release 12. 2(44)EY runs only on the Cisco ME 3400E Series Ethernet Access switch. Cisco ME 3400E Series Ethernet Access Switches. Cisco ME 3400E Series Ethernet Access Switches. Chapter Title. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Cisco IOS Release 12. Bias-Free Language. PDF - Complete Book (5. Prices and specifications are subject to. Bias-Free Language. Connector Specifications • 10/100 • SFP Module Connectors • Dual-Purpose Ports • 10/100 Ethernet Management Port • Alarm Input Port. ". Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Rel. End-of-Sale and End-of-Life Announcement for the Cisco IOS Releases 12. Published On: August 6ᵗʰ, 2019 02:05 Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide. Connect the other end of the cable to the Ethernet port on your DHCP-enabled PC. - Cisco ME 3400EG-12CS-M Switch. Release Notes for the Cisco ME 3400E and ME 3400 Ethernet Access Switches, Cisco IOS Release 12. Processor board ID FOC1728Z2UG. Read the detailed specifications of this ruggedized managed industrial ethernet switch in this document. Cisco IOS Release 12. Connect the AC power cord to the AC power input. By supporting double tags, the Cisco ME 3400 switch provides a virtual tunnel for each. Bias-Free Language. The Cisco implementation conforms to the OSPF Version 2 specifications with these key features:Switch Cisco Me3400e-Ts M Managable Harga Saudara di Tokopedia ∙ Promo Pengguna Baru ∙ Cicilan 0% ∙ Kurir Instan. Insert the power-supply module in the slot on the switch rear panel, and align and tighten the retainer screws. Check these items: • Bad or wrong SFP module. See full list on cisco. the specifications and information regarding the products in this manual are subject to change without notice. Cisco Systems, Inc. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Cisco IOS Release 12. Each Cisco module has an internal serial EEPROM that is encoded with security information. Cisco ME 3400E Series Ethernet Access Switches. An ME 3400E switch supports port-based 802. For syntax information, see the Cisco IOS Security Command Reference,. Cisco systems ethernet access switch getting started guide (16 pages) Switch Cisco ME 3400E Quick Start Manual. THE SPECIFICATIONS AND INFORMATION REGARDING. 3ah ● IEEE 802. Configuration Guides. This chapter describes how to configure the Spanning Tree Protocol (STP) on port-based VLANs on the Cisco ME 3400E Ethernet Access switch. Sell Us Your Surplus. If the switch is running the metro access image, you can configure only four ports as NNIs. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide OL-16485-03 Chapter 46 Troubleshooting Recovering from a Software Failure Recovering from a Software Failure Switch software can be corrupted during an upgrade, by downloading the wrong file to the switch, and by deleting the image file. Bias-Free Language. 2(52)SE, you can implement TWAMP on the Cisco ME 3400E Ethernet Access switch. This chapter describes the control-plane security feature in the Cisco ME 3400E Ethernet Access switch. Regulatory Compliance and Safety Information for the Cisco ME 3400E Ethernet Access Switch. ● IEEE 802. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Rel. 2(58)SE January 2012 Text Part Number: OL-9641-07. 89 kg) with no power-supply module. 2(50)SE. 0, We and our partners use cookies to give you the best online experience, including to personalise advertising and content. The switch uses the CNS connect profile to connect to the Configuration Engine. com Search or in the Cisco CommunityFor additional installation and configuration information, see the Cisco ME 3400E switch documentation on Cisco. Connector and Cable Specifications. 12. 35 lb (2. Cisco ME3400E Ethernet Access Switch Software Configuration Guide, Rel 12. 5 cm). The documentation set for this product strives to use bias-free language. Bias-Free Language. On the Cisco ME 3400E switch, RIP configuration commands are ignored until you configure the network number. Bias-Free Language. Cisco ME 3400E, ME 3400, and ME 2400 Ethernet Access Switch System Message Guide, Cisco IOS Release 12. The Cisco ME. 產品停產與終止銷售通知; English. You must supply the console cable if you did not order one with your switch. The documentation set for this product strives to use bias-free language. 2(52)SE. Cisco ME 3400E Ethernet Access Switch Software Configuration Guide, Release 12. 2(52)SE, you can implement TWAMP on the Cisco ME 3400E Ethernet Access switch. 2(60)EZ. This example shows how to enable the CNS event agent, set the IP address gateway to 10. CCIE R&S / CCSI : Yasser Auda. • Setting Up the Switch • Switch Models • Front Panel • Rear Panel Rear Panel •Cisco ME 3400E Series Ethernet Access Switches. 2(52)SE.